Specialised Contracting Solutions
3
Specialised Contracting Solutions
SPECIALISED
CONTRACTING SOLUTIONS
PLASTERING | PAINTING | CONCRETE | SURFACE FINISHING
SCS-HS-LEAD-001 / LEAD EXPOSURE MANAGEMENT

Lead-Based Paint Preparation / Removal JSEA

SCS-HS-JSEA-LEAD-001 · REV 2.0 · 26 SEPTEMBER 2026
STATUS
CONTROLLED — CURRENT
OWNER
Health & Safety Lead
APPROVED BY
SCS Director / Officer
SECTION
5 of 11
01
SECTION 01

JSEA LEAD-001 — Lead-Based Paint Preparation / Removal

Preparation, repair and removal of confirmed or presumed lead-based coatings in occupied and unoccupied buildings using SCS standard methods (Class A–C). Class D work is outside this JSEA.

ITEMDETAIL
People exposedSCS workers, residents and occupants (including children and vulnerable persons), pets, visitors, other contractors, members of the public
CompetenciesLead exposure information & acknowledgement (SCS-HS-FRM-LEAD-005); RPE fit test current (AS/NZS 1715) — within 12 months or since last face / model change; H-class extractor operation and pre-use check; Occupied property briefing; Work at height competency where access equipment is used
Plant / equipmentH-class extractor with correct filter / bag; Shrouded on-tool extraction (mechanical work only); Misting sprayer, scrapers, wet abrasives; Compatible chemical stripper (per SDS / TDS); Heavy-duty polythene, tape, barriers, signage; Labelled heavy-duty waste bags / containers; Decon kit: water, soap, wipes, disposable coveralls
PPE / RPERPE selected under AS/NZS 1715 (minimum P2; P3 where assessed); Disposable coveralls (Type 5/6) with hood; Nitrile / chemical-resistant gloves; Eye protection; Safety footwear / overshoes
Initial riskL4 × S4 = 16
Residual riskL2 × S4 = 8
Responsible personSite supervisor / foreman; H&S Lead for Class C
02
SECTION 02

Job steps, hazards and controls

#JOB STEPHAZARDS / CONSEQUENCESCONTROLS (HIERARCHY APPLIED)
1Confirm lead status, class and permitUnidentified lead disturbed; wrong method selected; asbestos presentCheck Permit to Proceed and asbestos status; confirm class A–C; stop if Class D or status unknown
2Brief crew and residentsResident, child or pet exposure; take-home contaminationResident notification, exclusion zone, signage; crew review this JSEA and sign on at prestart
3Set up containmentDust escape to living areas, soil or neighboursPolythene sheeting sealed at edges, windows / vents closed, HVAC off, barriers in place
4Pre-use equipment checksExtraction or RPE failureH-class airflow / filter / bag check; RPE fit / seal check; SDS / TDS on site
5Wet / manual preparationInhalation and ingestion of lead dustMist surfaces; wet scrape and wet sand; H-class vacuum as you go
6Chemical stripping (where selected)Chemical burns, vapour, contaminated residuesPer SDS / TDS; ventilation; gloves and eye protection; organic vapour controls where required; bag residues
7Mechanical preparation (Class C only)High dust generationShrouded on-tool extraction connected to H-class extractor; P3 RPE where assessed; stop if extraction fails
8Work at height interfaceFalls; dropped debris through containmentFollow access JSEA; catch sheets under work; tool tethering
9Clean-up and wasteResidual dust, contaminated runoffH-class vacuum then wet wipe; fold and bag sheeting; capture wash-water; label waste; lawful waste route
10Decon and hand-backTake-home contamination; resident re-entry to contaminated areaRemove coveralls in dirty zone; wash hands / face; bag tools; visual clearance and hand-back record
03
SECTION 03

Critical controls, hold points and stop-work

CRITICAL CONTROLS
  • Lead status confirmed or presumed and Permit to Proceed authorised before any disturbance
  • Containment and exclusion of residents, children and pets in place
  • No dry sanding / grinding, open flame, abrasive blasting, compressed air or dry sweeping
  • H-class extraction serviceable with correct filter / bag and airflow
  • RPE correct, fit test current, fit / seal check at each use
  • Clean / dirty transition, handwashing and decon before leaving the zone
HOLD POINTS
  • HOLD: no disturbance until lead status is Confirmed / Presumed / Not detected with evidence and the Permit to Proceed is authorised.
  • HOLD: asbestos status confirmed before disturbing any suspect material.
  • HOLD: Class C — monitoring decision recorded before Send to Prestart.
  • HOLD: Class D — STOP. Escalate to specialist / competent adviser.
STOP-WORK TRIGGERS
  • Dust escaping containment
  • Extractor stopped, alarm or filter / bag failure
  • RPE seal or filter failure
  • Resident, child or pet enters the control zone
  • Wash-water or runoff escapes capture
  • Unexpected lead or suspect asbestos found
  • Any request to dry sand, grind, blast or use open flame
VERIFICATION / REVIEW
Daily Lead Control Verification (SCS-HS-FRM-LEAD-003) completed pre-disturbance and at end of shift / hand-back; supervisor spot checks; H&S Lead review of Class C work.

Any change to lead status, method, class, occupancy, access, equipment or crew stops the task. Record the change, isolate, decon if needed and notify the supervisor / H&S Lead before work resumes.

No discharge of lead-contaminated water or debris to stormwater, soil or drains. All debris, sheeting and PPE bagged, labelled and removed by a lawful waste route.

Worker acknowledgement of this JSEA occurs on site through the daily Prestart — not in the SSSP.

—
SECTION —

Document approval

ROLENAME / POSITIONSTATUS
Prepared / reviewedHealth & Safety LeadREVIEWED
ApprovedSCS Director / OfficerAPPROVED
BUILDING SAFER SPACES FOR GENERATIONS
SCS-HS-JSEA-LEAD-001
REV 2.0 · 26 September 2026
CONTROLLED DOCUMENT · SPECIALISED CONTRACTING SOLUTIONS LIMITED
NZBN 9429043350858 · PAGE 1