JSEA 03/SCS Health & Safety Management System
Mobile Scaffold Tower - Erection and Use
Working at Height · Rev 1.0 · Approved master — controlled document
HIGH
Task steps, hazards and controls
Swipe or step through on mobile
| Step | Hazards | Controls |
|---|---|---|
| Assess ground and overhead | Uneven ground, overhead services | Level firm base, maintain 4m clearance from live lines |
| Erect tower | Collapse, falls during erection | Competent erector, safe build method, full guardrails and toeboards |
| Use and relocate | Tower overturn, dropped objects | Lock castors, dismount before moving, exclusion zone below |
Step 1 of 3
Assess ground and overhead
Hazards
Uneven ground, overhead services
Critical controls
Level firm base, maintain 4m clearance from live lines
Critical controls
- Erected by competent person to manufacturer instructions
- Outriggers deployed, castors locked, guardrails complete
- Never moved while occupied
Minimum PPE
Hard hatHi-visSafety footwearGloves
Sign-on register
0 signature(s) this session